Wow, I'm surprised that a year has passed since my last post. Largely, it has been due to my inability to get the editing tools to play well with the iPhone and now the iPad. Normally, I don't update my stuff on employer time, or employer equipment. Couple this with a VERY busy year, and me putting updates lower on the priority list, and here we are on Memorial Day weekend.

A lot has happened in the past 12 months. Too much for a single post, but let me sum up.

I'm working with a variety of Service Processors this year, making the work, and documenting what I've learned. Besides working at the BIOS level, I'm trying to determine if/how the settings can be modified from the OS's involved, and that is more difficult than I supposed. The main problem seems like the websites holding the IPMI drivers or libraries have disappeared after 3-4 years. (The biggest lesson here is to capture, collect, and archive these files for any hardware you acquire. Mergers and acquisitions contribute to the loss of the files, even as the instructions make it into a knowledge base.)

An old lesson re-learned, is that older Sun gear will ignore their serial console settings as soon as you plug a keyboard in! Your only clue, if you are logging the console output with Conserver or some other application, is a small line about detecting a keyboard. Removing the keyboard does NOT revert back to serial console output, you need to reboot the server with no keyboard attached. I knew this long ago, but then was thwarted when folks in a remote office attached a keyboard, and we didn't notice that console I/O had gone away.

I've also been doing a LOT of work with SNMP in the past 6 months, and I found an oddity with an MGE (which sold the line to APC, who then sold the line to Schneider Electric) room-sized UPS. The brains of the UPS uses a serial line to pass a data stream to the Network Interface shelf. If this streaming interface is removed, the SNMP cards do not get an update... But the cards simply report the LAST value for any queried OID. As a result, your only clue of a disconnect is seeing all results "flat-line". BUT, if you are also set up forSNMP traps, you will get also see a string that communications was lost with the UPS. This is a case where you really need to be able to parse Syslog and SNMP traps for interesting strings and send an alert.

Other UPS problems led to the integration of a UPS of Last Resort, so that core devices could track and log events with the big UPS. This included watching the serial output of the APC Smart-UPS 2200XL, plus SNMP integration into our monitoring system.

Another Big Project in the past year was due to a planned network outage. This was due to a planned partial power outage in the building. Unfortunately, some key devices also lost power, causing trouble, which could not send alerts via email because the network was down. We decided that we needed to make sure there was a second path out of the data center for critical alerts and messages. This led to integration with a FoxBox, a Network-connected cell-phone device, allowing SMS alerting AND control!

I've also added many more hosts to the host-to adapter database, but I only have a basic Cyclades console connection guide posted, and I still need to make a Digi page. (Cyclades was another fine example of collecting information from the web as soon as you hear about an acquisition!)

I'll make stronger efforts to post more frequently through the rest of 2010. thanks for reading.

-Zonker-

20071023

Whether we need DCD more than symetry

I'm very much in favor of a symmetrical RJ45 wiring schema for console servers, because it could minimize how many adapters I would need to stock. The advantages of a symmetrical pinout include using a simple 'rolled' cable to make a 'null-modem' connection between devices and adapters.

Now, I'm not picking any particular vendors wiring scheme as 'the best'. I'm espousing symmetry as the 'best way'. The problem is, this means having two Signal Ground pins, which usually means that DCD won't have a pin. (On an 8-wire RJ45 interface, you would have two ground leads, two data leads, two hardware flow control leads, and two hardware handshaking leads.)

Remember that today's Console Server has its roots in yesteryears Terminal Servers. The old TS used modems or terminals, to let remote users connect to hosts across the network. The hardware handshaking was used by the terminals to indicate if they were connected. With modems, they could be connected and powered, but it was DCD signals from the modem to the TS which told the TS whether an interface was 'on-line' with a remote user.

But, these days in console service, modems are a pretty rare thing. Still, I'll be the first to recognize that modems could be used to dial into a remote site and try to connect when the main WAN links are down. However, you can configure most modems to toggle the DSR lead to reflect the status of DCD, and you can configure most console servers to recognize the DSR lead as a signal that the device isn't ready. (So, I don't think we really need DCD in console service. I'll leave Dial-up Networking for later article.)

If you look at my Signals Page, in the RJ45 section, you'll notice that there are already a couple of symmetrical pinout schemes. But you can also see the wide variety of combinations that I've found so far. While pin 4 seems to be the most common pin for signal ground, its clear that not everyone uses pin for for the signal ground. That makes it harder to make an RJ45 signal tracer that works in all cases, so there is less incentive for a vendor to take on that project.

So, for the existing symmetrical RJ45 pinouts on my signals page, you'll notice that they use pins 4 and 5 as ground pins. Data pins are on pins 3 and 6. Handshaking is on pins 2 and 7, and flow control are on pins 1 and 8.

If you're asking "why can't we use pin 5 for DCD?", then you may not have thought about the issue deeply. The first problem comes when you use a rolled cable as a null modem, and you now connect two devices signal leads, but not their signal ground pins! You'll be replying on the chassis ground connections to provide the signal reference. Using these console servers in large data centers means that you may be connecting devices on different phases of the AC circuit, or even across two different Power Distrubtion Units (PDUs) or Uninterruptible Power Supplies (UPSs). The result could be burned out serial ports on your console server and the attached devices, or more sever damage to the units.

So, to summarize the vendors I know about today;

Symmetrical, with 2 grounds (9+ of 26):
Cisco, Logical Solutions SCS, Lantronics SCS-1600, Digi PortServer II, Xyplex 1600/1800, iTouch/MRV in-Reach lines, Juniper Networks (J-series devices, and many NetScreen devices), Server Technology CDU consoles, and Sun Microsystems console/TTY ports

Symmetrical, except for 1 ground and DCD (3 of 26):
Digi CM, Digi STS-1610, Opengear CM

Of the 27 console connections I've documented, 15 use pin 4 for ground, and 9 use pin 6 for ground. (Keep that in mind if you are making your own RJ45 signal tracers.) And of the 9 symmetrical pinouts, eight of them use pins 4 and 5 for ground, and one uses pin6 3 and 6.

It seems to me that other vendors (who are not making console servers) have been choosing the Cisco wiring scheme (Juniper, Sun, Server Technology). Lantronix picked the null-modem compliment to the Cisco pinout. Those choices have been good for me, since it simplifies some of the deployments that I work on. It's interesting to note that the Xyplex/iTouch/MRV pinouts are almost identical, except that pins 1 and 8 (the flow control leads) are inverted from the Cisco schema. (So, if you don't care about flow control, you can mix-and-match these devices with the Cisco-schema cousins.)

I'm under the impression that some vendors are considering adopting a different wiring scheme for their future product series. I'd strongly urge that they consider adopting a symmetrical schema, and I'd also strongly encourage them to consider using an existing schema, rather than trying to come up with a unique schema. And I'm always interested in discussing it in person, though an email on the topic is also welcome.